For the complete documentation index, see llms.txt. This page is also available as Markdown.

Paulmann 50064 Light Bulb

Pair, register, and map the Paulmann 50064 tunable-white Zigbee bulb in Chirp, with all the quirks.

This is a hardware-specific walkthrough for the Paulmann SmartHome LED spot, model 50064 — a Zigbee 3.0 CCT (tunable-white) bulb we tested end-to-end with Zigbee2MQTT and Chirp's MQTT connector. If you have this exact bulb, follow these steps to pair it, register it in Chirp, and map its readings.

If you have a different Zigbee bulb or device, you don't need this page — the generic flow applies. Pair the device through Z2M following your manufacturer's instructions, then register it in Chirp the same way as any other Z2M-bridged device. The Paulmann 50064 happens to be the bulb we had in hand for the testing — the procedure transfers cleanly to other Zigbee devices.

The Zigbee2MQTT model reference documents its supported controls and payload ranges. The pairing notes below describe the setup used for this guide.

What is the Paulmann 50064 light bulb?

  • Type: CCT (correlated color temperature) tunable-white LED. Adjusts brightness and color temperature, but not color (no RGB).

  • Color temperature range: 150–500 mired (about 6667K daylight to 2000K candle-warm).

  • Power: mains-powered; confirm the fitting and electrical rating on your unit before installation.

  • Zigbee profile: Zigbee 3.0, identifies as Paulmann SmartHome led spot (50064) in Z2M.

  • Z2M auto-identifies it — once paired, Z2M shows the brand and model in the Devices tab without manual selection.

What works:

  • Brightness and color-temperature control via the Z2M web UI, MQTT /set commands, or any home-automation system that publishes to MQTT.

  • State changes initiated via MQTT or the Z2M web UI generate confirmation publishes that flow through Chirp into the Mapping tab and Logs tab.

Behavioral quirk to know up front: physical wall-switch toggles do not generate MQTT publishes on this bulb. The bulb's firmware only reports state changes that arrived over Zigbee, not changes caused by mains power-cycling. If you flip a wall switch and then check the Logs tab, expect to see nothing new — that's the bulb's design, not a Chirp or Z2M bug. To verify state in Chirp during setup, drag the brightness slider in the Z2M web UI or send a /get poll. See Troubleshooting for the full list of "what counts as a publish."

What do I need for the Paulmann 50064?

  • Z2M is installed and running. If not, follow Setting up Zigbee2MQTT and the Sonoff ZBDongle-E coordinator walkthrough (or the equivalent for your coordinator) before continuing here.

  • The bulb is screwed in and the wall switch is in the on position. It's powered, even if it's currently lit on factory-default settings.

  • The bulb is within ~2 meters of the coordinator for initial pairing. After joining, you can move it anywhere — Zigbee mesh routing handles range.

How do I pair the Paulmann 50064 bulb?

The Paulmann 50064 uses a 5-cycle reset pattern.

  1. Open Permit join in Z2M first. In the Z2M web UI at http://localhost:8080, click the green shield icon at the top labeled Permit join (All). The Zigbee network is now open for 180 seconds.

  2. Power-cycle the bulb through 5 on-cycles. Use the wall switch:

    • on → off → on → off → on → off → on → off → on

    • That's 5 on-states with an off-state between each. Hold each state for ~2 seconds. Don't rush — too fast and the bulb may not register the cycle.

  3. On the 5th on-cycle, the bulb blinks rapidly. This is the factory-reset confirmation. Pairing mode is now active and the bulb is on.

  4. Stop. Leave the bulb on. Don't touch the switch. This is the most common mistake — people see the blink and immediately do another off/on cycle, which restarts the reset sequence and aborts the join attempt.

  5. Wait 10–30 seconds. The bulb joins the Zigbee network and appears in Z2M's Devices tab, identified by its IEEE address (0x...).

  6. Z2M auto-identifies the model. The Devices tab shows Paulmann SmartHome led spot (50064) next to the device.

If pairing doesn't happen within ~60 seconds:

  • The 180-second Permit join window may have closed. Click Permit join again.

  • The bulb may already be paired to a previous Zigbee network (rare for new bulbs but possible if you bought it second-hand). Repeat the 5-cycle reset to factory-default it again.

  • Some Paulmann firmware revisions require 10 cycles instead of 5. Try 10 if 5 doesn't trigger the blink.

  • Move the bulb closer to the coordinator. 1–2 meters is the safest range for first pairing.

How do I rename the Paulmann 50064 in Zigbee2MQTT?

When the bulb pairs, its initial friendly name is its IEEE address. Rename it to something readable — that name will become the device-level MQTT topic Z2M publishes to AND the Device ID you'll use in Chirp.

In the Z2M web UI:

  1. Click the bulb's row in the Devices tab.

  2. Click the pencil icon next to the name at the top of the detail panel.

  3. Type a new name. Use a clear name such as TableLampLivingRoom or table_lamp_living_room. Chirp preserves case and spaces; its Device ID must match the friendly name exactly.

  4. Press Enter or click the checkmark.

The example friendly name we'll use in this page: TableLampLivingRoom.

After renaming, Z2M publishes to a topic that starts with your Cloud MQTT connector's prefix:

What does the Paulmann 50064 publish?

When the Paulmann 50064 sends a state update, the payload looks like this:

Full field reference:

Field
Type
Range
Notes

state

string

"ON", "OFF"

TOGGLE is a command input, not a reported steady state. String, not boolean. Map to a String-typed metric in Chirp.

brightness

integer

0–254

0 turns the bulb off on some firmware versions. Note: 0–254, not 0–255 or 0–100.

color_temp

integer

150–500 mired

See the Mirek-scale table below.

color_temp_startup

integer or null

150–500, 65535, or null

"Start Up Color" — what color temperature the bulb turns on as when power is restored. null = not configured; the bulb uses its firmware default on cold power-on. 65535 = sentinel for "restore previous color temperature." Any number in 150–500 = a fixed mired value to apply on every power-on. Set via a /set command with an explicit numeric value to configure.

power_on_behavior

enum

off, on, toggle, previous

Behavior after a power loss. Send via /set to configure.

effect

enum

blink, breathe, okay, channel_change, finish_effect, stop_effect

Command-only effects. Send via /set; this field is not published as a state reading and cannot be read with /get.

linkquality

integer

0–255

Zigbee link quality. Signal-quality reading useful during troubleshooting.

color_mode

string

"color_temp"

Reported by the setup used for this guide. Map it if your bridge publishes it; optional fields can differ with firmware and bridge versions.

Mirek scale (color_temp values)

The Mirek (or "mired") scale is the inverse of Kelvin: lower Mirek = cooler/bluer light, higher Mirek = warmer/more amber. The formula is mired = 1,000,000 / Kelvin.

Z2M ships named presets for the Paulmann 50064:

Preset name
Mired
Approximate Kelvin
Description

coolest

150

6667K

Daylight / blue-white

cool

250

4000K

Natural white

neutral

370

2703K

Warm white

warm

454

2203K

Candle-like

warmest

500

2000K

Very warm amber

When you map color_temp in Chirp, choose a numeric metric. The unit is mired (lower = cooler).

If this bulb replaces one already represented in Chirp, keep that digital device and reconnect its MQTT source and measurement mappings. Review any saved commands for the replacement model. The steps below describe a new registration; Sensor Details covers the replacement approach.

How do I register the bulb in Chirp?

Once Z2M is publishing to a topic Chirp can see (verify via the connector's Last data received), register the device:

  1. Connectors → your MQTT connector → Add device.

  2. Device ID: TableLampLivingRoom (or whatever whitespace-free friendly name you chose). It must match the Z2M friendly name byte-for-byte.

  3. Create and save the named digital device, then open Connection and select your MQTT connector.

  4. Connection — topic routing:

    • MQTT Topic for device ID: zigbee2mqtt/{{deviceId}}

    • Where to get the device ID: Topic (default).

    • Topic Telemetry: leave empty. The Paulmann publishes a flat JSON payload — Chirp parses all keys automatically.

  5. Click Save, then open Mapping to reach the per-key rows. See MQTT Devices for the complete workflow.

  6. Mapping — Pass 1: add a row per metric you want, but leave Device data key empty. Recommended initial set:

    Normalized key
    Type
    Data type

    State

    String

    Telemetry

    Brightness

    Integer

    Telemetry

    Color Temperature

    Integer

    Telemetry

    Color Mode

    String

    Telemetry

    Link Quality

    Integer

    Telemetry

    If a normalized key you want doesn't exist, use + Add new metric and create one. The modal handles both the normalized name and the underlying sensor template.

    Color Mode must be a String, not an Integer. It's tempting to default to a numeric type for what looks like a small enumerated value, but the actual payload value is a string ("color_temp"). A numeric metric rejects this text instead of storing it. The same is true for state ("ON"/"OFF").

  7. Click Save.

  8. Generate a publish. Open the bulb in the Z2M web UI and drag the brightness slider, or use the on/off toggle. Z2M sends a /set command, the bulb confirms the new state, and Z2M publishes the confirmed payload — that's the publish Chirp needs.

  9. Mapping — Pass 2: reopen the device record. The Device data key dropdowns now list the keys received from the bulb. Match each row:

    Mapping row
    Device data key

    State

    state

    Brightness

    brightness

    Color Temperature

    color_temp

    Color Mode

    color_mode

    Link Quality

    linkquality

  10. Click Save again.

Pass 3 — add Start Up Color after the first publishes arrive

Once the bulb has been publishing for a little while, the Device data key dropdown shows one more useful field: color_temp_startup. The bulb only emits this in some payloads — typically after a /get poll or after explicitly setting it — so it often isn't visible during Pass 2. Treat it as a third pass:

  1. Reopen the device record. Confirm the Device data key dropdown now lists color_temp_startup as an option (if not, force a publish that includes it: send a /get request, or send a /set with a color_temp_startup value).

  2. Click Add key in the Mapping sub-tab.

  3. Pick or create a Start Up Color normalized key (Integer type, Telemetry data type).

  4. Set the Device data key to color_temp_startup.

  5. Click Save.

Mapping row
Device data key
Type
Data type

Start Up Color

color_temp_startup

Integer

Telemetry

What "Start Up Color" means: the color temperature the bulb turns on as when power is restored. A specific number (150–500 mired) means "always cold-start at this color." 65535 means "remember the previous setting and restore it on power-on." null means it isn't configured — the bulb uses its firmware default. Useful in homes where you want the lamp to always come on warm regardless of how it was last left.

This three-pass progression — register the obvious fields first, fill in Device data keys after the first publish, then add the late-discovered field — is normal for MQTT mapping. Most devices have at least one field you'll only see once data is flowing.

After the three passes, the Value column on the Mapping tab populates with the bulb's current state across all six metrics. Generate one more publish (drag the Z2M slider) to confirm records arrive in the Logs tab — that's your end-to-end verification.

Which behaviors look like problems but aren't?

  • Mapping tab Value column updates but Logs tab is empty. Normal after Pass 2 if you saved Device data keys after the most recent publish. Generate a fresh publish from the Z2M web UI.

  • color_mode always shows "color_temp". This bulb has no RGB capability. The field is always color_temp for CCT bulbs.

  • color_temp_startup shows 65535 or null. 65535 is the sentinel for "restore previous color temperature on power-on." null means it hasn't been configured and the bulb uses its firmware default. Set a specific number (150–500 mired) via /set if you want a fixed color on every cold power-on.

  • color_temp_startup doesn't appear in early payloads. The bulb only emits this field in certain payloads — typically after a /get poll or after the field has been explicitly set. If your Device data key dropdown doesn't show it during Pass 2, that's normal — see Pass 3 above.

  • Multiple publishes from one /get request. Z2M polls Zigbee attribute clusters separately, so one /get produces 2–4 publishes back as the cluster responses arrive. Normal — not an error.

  • Wall-switch toggle produces no Logs entry. As covered above — this bulb doesn't publish on physical power-cycle. Use the Z2M web UI to generate publishes for setup-time verification.

Where to go next

Last updated